AH(R)/HH/M(R) Series Slurry Pump
The AH(R)/HH/M(R) series slurry pumps are horizontal centrifugal pumps. They are specifically designed for handling high-density, highly abrasive, and highly corrosive slurries, suitable for applications such as mill slag discharge, coarse sand, coarse tailings, phosphoric acid, mineral concentrate, heavy media, lime grinding, and fine tailings. The pump body components in contact with the fluid are made of highly wear-resistant and corrosion-resistant alloys, rubber, or polyurethane, making them particularly suitable for conveying highly abrasive, high-density slurries.
AH(R)/HH/M(R) Series Slurry Pump
Horizontal, single-stage, single-suction, cantilever, double-casing pump;
Wide flow path, excellent anti-clogging performance, superior cavitation performance;
High flow rate, high head, can be used in multi-stage series;
Adjustable ester lubrication for the support frame;
Optional materials for flow parts: rubber lining, polyurethane, and various wear-resistant metals;
- Product features
- Working conditions
- Model Meaning
- Support type description
- Construction design
- Shaft seal module design
H(R), HH, and M(R) type pumps are cantilevered, horizontal centrifugal slurry pumps. They are suitable for conveying abrasive or corrosive slurries in industries such as metallurgy, mining, coal, power, and building materials.
AH(R) and HH, also known as heavy-duty slurry pumps, are suitable for conveying highly abrasive, high-concentration slurries or low-concentration, high-head slurries. Within permissible pressure ranges, this type of pump can also be used in multi-stage series.
The HH type pump is suitable for conveying low-concentration, high-head slurries or high-concentration, low-abrasion, high-head slurries.
M(R) is a medium-duty slurry pump, suitable for conveying fine-particle, medium-concentration slurries.
AH and M type pumps have replaceable wear-resistant metal or rubber liners, and the impeller can be made of wear-resistant metal or rubber materials.
The HH type pump has only wear-resistant metal lining and impeller. Rubber flow parts are suitable for conveying slurries containing fine, non-sharp particles.
The shaft seals of AH(R), HH, and M(R) type pumps can be packing seals, impeller seals, or mechanical seals. The pump outlet position can be installed at eight different angles in 45-degree intervals as needed.
Capacity: 3.6-5400 m³/h
Head: 6-125 m
Processable Solids: 0-130 mm
Concentration: 0%-70%

| Frame Type | A | B | C | D | E | R | F | G | S | T |
| Max.Power(kw) | 7.5 | 15 | 30 | 60 | 120 | 300 | 260 | 600 | 560 | 1200 |
| Frame Weight (kg) | 17 | 24 | 45 | 77.5 | 154 | 228 | 555 | 1006 | 546 | 1156 |
| Amount of Shaft Sealing Water(l/s) | 0.15 | 0.25 | 0.35 | 0.55 | 0.70 | 0.70 | 0.70 | 1.20 | 1.20 | 1.60 |
From suction view, there can be eight installation angle.
B support type only has four installation angle, but CV transmission is not applicable.





| Pump Model | Allowable Max.Power (kw) |
Clear Water Performance | ||||||
| Capacity Q | Head H (m) |
Speed n (r/min) |
Max.Eff. (%) |
NPSH (m) |
Impeller. Dia. (mm) |
|||
| m³/h | l/s | |||||||
| 1.5/1B-AH | 15 | 12.6-28.8 | 3.5-8 | 6-68 | 1200-3800 | 40 | 2-4 | 152 |
| 2/1.5B-AH | 15 | 32.4-72 | 9-20 | 6-58 | 1200-3200 | 45 | 3.5-8 | 184 |
| 3/2C-AH | 30 | 39.6-86.4 | 11-24 | 12-64 | 1300-2700 | 55 | 4-6 | 214 |
| 4/3C-AH | 30 | 86.4-198 | 24-55 | 9-52 | 1000-2200 | 71 | 4-6 | 245 |
| 4/3D-AH | 60 | 86.4-198 | 24-55 | 9-52 | 1000-2200 | 71 | 4-6 | 245 |
| 6/4D-AH | 60 | 162-360 | 45-100 | 12-56 | 800-1550 | 65 | 5-8 | 365 |
| 6/4E-AH | 120 | 162-360 | 45-100 | 12-56 | 800-1550 | 65 | 5-8 | 365 |
| 8/6E-AH | 120 | 360-828 | 100-230 | 10-61 | 500-1140 | 72 | 2-9 | 510 |
| 8/6R-AH | 300 | 360-828 | 100-230 | 10-61 | 500-1140 | 72 | 2-9 | 510 |
| 10/8ST-AH | 560 | 612-1368 | 170-380 | 11-61 | 400-850 | 71 | 4-10 | 686 |
| 12/10ST-AH | 560 | 936-1980 | 260-550 | 7-68 | 300-800 | 82 | 6 | 762 |
| 14/12ST-AH | 560 | 1260-2772 | 350-770 | 13-63 | 300-600 | 77 | 3-10 | 965 |
| 16/14TU-AH | 1200 | 1368-3060 | 380-850 | 11-63 | 250-550 | 79 | 4-10 | 1067 |
| 20/18TU-AH | 1200 | 2520-5400 | 700-1500 | 13-57 | 200-400 | 85 | 5-10 | 1370 |
| 1.5/1B-AH(R) | 15 | 10.8-25.2 | 3-7 | 7-52 | 1400-3400 | 35 | 2-4 | 152 |
| 2/1.5 B-AH(R) | 15 | 25.2-54 | 7-15 | 5.5-41 | 1000-2600 | 50 | 2.5-5 | 178 |
| 3/2C-AH(R) | 30 | 36-75.6 | 10-21 | 13-39 | 1300-2100 | 55 | 2-4 | 213 |
| 4/3C-AH(R) | 30 | 79.2-180 | 22-50 | 5-34.5 | 800-1800 | 59 | 3-5 | 245 |
| 4/3D-AH(R) | 60 | 79.2-180 | 22-50 | 5-34.5 | 800-1800 | 59 | 3-5 | 245 |
| 6/4D-AH(R) | 60 | 144-324 | 40-90 | 12-45 | 800-1350 | 65 | 3-5 | 365 |
| 6/4E-AH(R) | 120 | 144-324 | 40-90 | 12-45 | 800-1350 | 65 | 3-5 | 365 |
| 8/6E-AH(R) | 120 | 324-720 | 90-200 | 7-49 | 400-1000 | 65 | 5-10 | 510 |
| 8/6R-AH(R) | 300 | 324-720 | 90-200 | 7-49 | 400-1000 | 65 | 5-10 | 510 |
| 10/8ST-AH(R) | 560 | 540-1188 | 150-330 | 12-50 | 400-750 | 75 | 4-12 | 686 |
| 12/10ST-AH(R) | 560 | 720-1620 | 200-450 | 7-45 | 300-650 | 80 | 2.5-7.5 | 762 |
| 14/12ST-AH(R) | 560 | 1152-2520 | 320-700 | 13-44 | 300-500 | 79 | 3-8 | 965 |
| 16/14 TU -AH(R) | 1200 | 1224-2754 | 340-765 | 9-43 | 250-450 | 82 | 3-8 | 1067 |
| 20/18TU-AH(R) | 1200 | 2268-4860 | 630-1350 | 11-46 | 200-350 | 82 | 2-8 | 1372 |
| 10/8E-M | 120 | 540-1440 | 150-400 | 14-60 | 600-1000 | 73 | 4-10 | 549 |
| 10/8R-M | 300 | 540-1440 | 150-400 | 14-60 | 600-1000 | 73 | 4-10 | 549 |
| 1.5/1C-HH | 30 | 16.2-34.2 | 4.5-9.5 | 25-92 | 1400-2200 | 20 | 2-5.5 | 330 |
| 3/2D-HH | 60 | 68.4-136.8 | 19-38 | 25-87 | 850-1400 | 47 | 3-7.5 | 457 |
| 4/3E-HH | 120 | 126-252 | 35-70 | 12-97 | 600-1400 | 50 | 2-5 | 508 |
| 6/4F-HH | 260 | 324-720 | 90-200 | 30-118 | 600-1000 | 64 | 3-8 | 711 |
| 8/6S-HH | 560 | 468-1008 | 130-280 | 20-94 | 500-1000 | 65 | 4-12 | 711 |
Remark:
1.Capacity range recommended:50%Q’≤Q5≤110%Q(Q’ Appropriate to capacity at highest efficiency point).
2.NPSH: appropriate to point Q recommended at highest speed.