x
Send Your Inquiry Today
Quick Quote
  • HD type vertical diagonal flow pump
  • HD type vertical diagonal flow pump

HD type vertical diagonal flow pump

The HD type diagonal flow pump is a vertical pump developed by integrating excellent hydraulic models, reasonable structures and advanced manufacturing methods at home and abroad. It can transport clean water, rainwater, seawater, sewage and other media with a temperature not exceeding 55°C. It is mainly used in cooling water circulation pumps in power plants, seawater circulation pumps in seawater desalination plants, vaporization pumps for liquefied natural gas, etc. It can also be used for water supply and drainage in cities, industries, mining and farmland.

Performance range:

Flow Q: (0.27~16.7)m³/s

Lift H: (5.7~60) m

HD type vertical diagonal flow pump

Pump shaft with large protective tube structure:

The pump shaft protective tube adopts a large protective tube structure to prevent the core-pulling component from being unable to be extracted after the pump has been used for several years, making maintenance more convenient.

Excellent service:

The pump shaft protective tube adopts a large protective tube structure to prevent the core-pulling parts from being unable to be extracted after the pump has been used for several years, making maintenance more convenient.

Sealed lubricated guide bearing:

Used in seawater and media with high sand content. In order to extend the service life of the pump shaft and guide bearing, our company developed a closed lubricating water system to isolate the shaft and guide bearing from the medium.

Embedded polymer materials:

Products suitable for pump stations can be specially designed according to user requirements. We attach great importance to the high performance, high quality and delivery time of our products.

  1. Installation method

a.Co-seating (single foundation) installation (see structural diagrams 1, 2, 3, 4)

Figures 1 and 2 show the non-extractable structure with the pump outlet pipe above the base layer and the rotor extractable structure; Figures 3 and 4 show the non-extractable structure with the pump outlet pipe below the base layer and the rotor extractable structure.

b.Separate type (double foundation) installation (see structure diagram 5)

The pump outlet pipe is between the two foundation layers and has two structures: pumpable and non-pumpable.

  1. The lower part of the pump is submerged in water. The suction port is a vertically downward bell mouth suction. The suction pool is a wet pit type, or it can be designed as a dry pit type according to needs.
  2. The pump can be designed as withdrawable or non-drawable (rotor part or inner casing)
  3. The blades of the impeller can be made into non-adjustable (fixed blades), half-adjustable or fully-adjustable forms.
  4. The pump bearings can be rubber bearings, Sailon bearings or AR bearings. Sailon bearings and AR bearings can be started without external water lubrication.
  5. The axial thrust of the pump is borne by the motor. In some small pumps, the axial thrust is borne by the pump itself.
  6. The pump impeller is usually one-stage, but can also be designed into multiple stages as needed.

HD type diagonal flow pump single foundation outlet pipe structure diagram on the foundation

Structural diagram of HD type diagonal flow pump single foundation outlet pipe under the foundation

 

Features
  1. Safe, reliable and long service life.
  2. The pump has high efficiency, ranging from 85% to 90%, and the high efficiency area is wide.
  3. The pump has good cavitation performance and small excavation depth.
  4. The pump shaft power curve is relatively gentle, and the pump is not prone to overpowering due to working conditions deviation during operation.
  5. Small size, small floor space, and easy construction of water inlet channels.
  6. The structure is reasonable and easy to assemble and disassemble. The rotor does not need to be pumped into the pool for maintenance, which is convenient for maintenance.

 

Name, material, quantity of main parts and details of wearing parts and spare parts (see table below)
serial number Part name quantity unit Material Remark
clear water sea water | Sea water Ⅱ
1 suction bell tube 1 piece HT250/Q235-A HT250NI2Cr/

0Cr18Ni9Ti/316

Duplex steel 2205
2 impeller 1 piece 7G3511Cr18Ni9 316/316L Duplex steel 2205/2507
3 shaft 1~4 piece 45/40Cr 316/316L Duplex steel 22055/2507
4 Guide vane body 1 piece HT250/Q235-A HT250NI2Cr/0Cr18Ni9Ti/316 Duplex steel 2205/2507
5 Internal protective tube 1 piece Q235-A 0Cr18Ni9Ti/316 Duplex steel 2205
6 external take over 1 piece HT250/Q235-A HT250NI2Cr/

0Cr18Ni9Ti/316

Duplex steel 2205
8 Bend pipe 1 piece HT250/Q235-A HT250NI2Cr/

0Cr18Ni9Ti/316

Duplex steel 2205
9 pump cover 1 piece HT250/Q235-A 0Cr18Ni9Ti/316 Duplex steel 2205
10 pump base 1 piece HT250/Q235-A 0Cr18Ni9Ti/316 Duplex steel 2205
11 base ring 1 piece HT250/Q235-A Cr-Ni cast iron/Q235-A+ coating Cr-Ni cast iron+coating/Q235-A+coating
12 Motor base 1 piece HT250/Q235-A HT250/Q235-A HT250 or Q235-A
13 Coupling parts 1 set HT250 /35 0Cr13Ni4Mo /
316
Duplex steel 2205
14 Adjusting nut 1 piece 45 0Cr13Ni4Mo /

316

Duplex steel 2205
15 stuffing box 1 piece HT250 0Cr18Ni9Ti/316 Duplex steel 2205
16 Guide bearing 1~4 piece Rubber/Salon Salon Salon/AR Consumable parts (quantity determined by structure)
17 packing bushing 1 piece 1Cr18Ni9 chrome plated 1Cr18Ni9 chrome plated Duplex steel 2205 Ditto
18 Shaft sleeve 1~4 piece 1Cr18Ni9 chrome plated 1Cr18Ni9 chrome plated Duplex steel 2205 Ditto
19 Pump body sealing ring 0~2 piece HT250 1Cr18Ni12MoTi tin bronze/Duplex steel 2205 Ditto
20 Impeller seal ring 0~2 piece O235-A/1Cr18Ni9 0Cr18Ni12MoTi Duplex steel 2205/2507 Ditto
21 filler 1 box Ramie Ramie/carbon fiber Ramie/carbon fiber Ditto
22 Telescopic section 1 set HT250/Q235-A 0Cr18Ni9Ti/316 Duplex steel 2205 When ordering, please indicate whether to bring
23 “Lubricating Water Cooling Accessory” 1 set (Pressure gauges, regulating valves, flow indicators and small pipes, etc.) When ordering, please indicate whether to bring
Complete supply scope
Complete set scope name quantity Remark
host computer Pump 1 unit
1 unit
annex Auto exhaust valve 1 piece
Lubricating water device 1 group
tool Special disassembly and assembly tools 1 group
Ordering instructions
  1. In addition to the performance parameters on the sample, the pump performance can also be ordered with other performance parameters;
  2. For the pump structure, please refer to any one of Figures 1 to 5, or put forward corresponding structural requirements according to the list of 5 structural diagrams, and clarify whether to make requirements for the position where the pump axial water thrust is received (on the pump or on the motor);
  3. Make requirements for the material type of main parts or propose pumping media.
Update cookies preferences