Prefabricated Smart Pump Station
Integrated smart pump room is a systematic integrated product of Shanghai Kaiquan, relying on more than 20 years of continuous research in the water supply industry, strict quality control system, and optimal parameter matching. The pump room mainly consists of digital integrated full frequency conversion water supply equipment, pipe valve system, network communication system, video monitoring system, access control and security system, ventilation and dehumidification system, noise reduction and shock absorption system, insulation and heat insulation system, and other parts.
The integrated smart pump room fully considers factors such as outdoor, rainproof, thermal insulation, noise reduction, and security for systematic design and development. With the help of current Internet of Things technology, remote monitoring and intelligent operation and maintenance of equipment can be achieved. This product is mainly used for water supply renovation in old residential areas with multiple floors, rural urbanization construction, etc. It does not require the construction of pump rooms and has obvious advantages such as short renovation cycle and low investment and operation costs.
Prefabricated Smart Pump Station
The integrated smart pump room integrates multiple water supply modes such as water tank transfer pressurization, tank type non negative pressure (stacked pressure), and box type non negative pressure required for secondary water supply equipment. The pump room is equipped with Kaiquan’s fifth generation digital integrated full frequency conversion water supply equipment and a highly reliable dual PLC control system (which has obtained an invention patent), greatly improving the safety, reliability, and intelligence level of the unit. In addition, the control cabinet of the Kaiquan pump room system has multiple configurations and can be connected to Modbus RTU Modbus TCP PROFIBUS PROF-INET. Wireless remote module 2G/4G and other communication protocols meet the needs of different customers, greatly simplifying the implementation of smart IoT devices. The latest solution to adapt to harsh environments, digital integrated full frequency conversion dual PLC technology, minimizes system failure rates. A comprehensive service system and nationwide service network provide strong guarantees for timely after-sales service.
- Model Specification
- Principle of integrated smart pump room
- WFY Pump Station Interial Structure
Examples of the meaning of the WFY integrated smart pump room model are as follows:
Examples of KQF integrated smart pump room model meanings are as follows: 
The schematic diagram of WFY integrated smart pump room is as follows:

| 1 | Service Valve |
| 2 | filter |
| 3 | backflow-prevention device(optional) |
| 4 | Steady flow tank |
| 5 | surge tank |
| 6 | Pressure gauges and sensors |
| 7 | High strength ball valve |
| 8 | Check valve |
| 9 | water pump |
| 10 | Electric control cabinet |
| 11 | multifunctional Smart cabinet |
| 12 | dehumidifier |
| 13 | Axial flow fan |
| 14 | Outdoor pump station |
| 15 | Electromagnetic Flowmeter |
The schematic diagram of KQF integrated smart pump room is as follows:

| 1 | Service Valve |
| 2 | filter |
| 3 | electric valve |
| 4 | water box |
| 5 | surge tank |
| 6 | Pressure gauges and sensors |
| 7 | High strength ball valve |
| 8 | Check valve |
| 9 | water pump |
| 10 | Electric control cabinet |
| 11 | multifunctional Smart cabinet |
| 12 | dehumidifier |
| 13 | Axial flow fan |
| 14 | Outdoor pump station |
| 15 | Electromagnetic Flowmeter |
| 16 | Ultraviolet sterilizer |

KQF Pump Station Interial Structure

Kaiquan Integrated Intelligent Pump House integrates steel structure pump house, pump house management system, digital integrated variable frequency water supply equipment, video security system, and remote monitoring system. It utilizes intelligent Internet of Things technology to achieve remote monitoring and intelligent operation and maintenance of the pump house, with many advantages such as factory integration, overall delivery, convenient installation, and fast water supply. The combination of intelligent water supply, intelligent Internet of Things, intelligent security, and intelligent constant temperature improves the level and efficiency of pump room management, ensuring that the intelligent pump room is the most cost-effective solution in terms of water supply safety, reliability, and intelligence.
Professional outdoor pump room design
Noise reduction, insulation, fire prevention, earthquake resistance, wind resistance, corrosion resistance, and highly integrated environment can meet the material requirements of stainless steel pump rooms.
Quickly build a landscape pump room
Integrated supply, on-site assembly, rapid construction, exponentially reduced land occupation, and the ability to construct green belt landscape pump rooms.
Simplify the land use program for pump rooms
Integrated smart pump room, easy to move assets, land for pump room can be leased, avoiding land civil engineering approval matters.
Digital integrated full frequency conversion unit
Redundant design, safe and reliable; Digital integrated design with low failure rate; Fully variable frequency design, safe, efficient, and stable; Overflow components made of 304 stainless steel, precision electropolishing treatment, hygienic and rust resistant.
Intelligent water supply control
The system comprehensively improves the perception ability of water supply equipment, monitors pressure, flow, water quality, power parameters, energy efficiency parameters, etc. from multiple dimensions, and intelligently utilizes analysis and calculation results to achieve the optimal parameter operation of the unit.
Intelligent security monitoring
Personnel access permission management, remote video monitoring and archiving, intrusion voice warning, smoke, temperature, humidity, water flooding and other environmental status monitoring alarms.
Intelligent IoT operation and maintenance
The integrated application of automation, digitization, informatization, and intelligence technologies improves the level and efficiency of pump room management, ensuring the safety and stability of water supply for residents in the last mile.
Intelligent constant temperature system
Intelligent control of pump room environmental temperature through ventilation and heating in cold northern regions; In the humid and hot areas of the south, the pump room temperature is intelligently controlled through ventilation and refrigeration to ensure the safe and stable operation of the electrical system at constant temperature.
| Model specifications | WFYV/KQFV full series | |
| Water supply flow rate | 5-135m3/h,determined by device model | |
| Water supply pressure | 20-160mHzO,determined by device model | |
| Actual pressurization range of water pump | 40%100%Pump head (fully variable frequency control) | |
| Constant voltage accuracy | ≤1mH20 | |
| stability time | ≤5s | |
| operating mode | Main and backup control, manual operation, automatic control, centralized control (bus remote control) | |
| start-stop mode | Variable frequency pump soft start and soft stop | |
| control mode | Equipment outlet constant pressure control or automatic variable pressure control (simulating terminal constant pressure control) or other | |
| Operation mode | QB (fully variable frequency operation) | |
| interface | Digital instruments, true color touch screens | |
| Protection/Alarm | Short circuit, overload, phase loss protection, indicator light alarm | |
| Equipment material | The overcurrent section (pump, valve, tank, pipeline) is made of food grade 304 stainless steel | |
| working conditions | Installation conditions | Concrete frame with sufficient load-bearing capacity |
| power supply | 380V (+10%, -15%), 50Hz, should have a good grounding wire, and the grounding resistance should be less than 4 ohms | |
| environment | Outdoor installation -30 ℃~60 ℃, note | |
| Altitude, vibration | Altitude below 1000m, seismic resistance below level 8, wind resistance below level 10 | |
| relative humidity | <90% (20 ℃) without condensation (electronic control part) | |
Note: The pump station is equipped with an automatic heating system when the ambient temperature is around -20 ℃, and an air conditioning and refrigeration system when the ambient temperature is around 30 ℃.