Sewage Lifting Device and Oil Separation Equipment

The integrated sewage lifting device is a system solution developed to address the shortcomings of traditional sewage lifting. It mainly consists of a water tank, a submersible sewage pump, valves and pipeline accessories, a liquid level controller and an electrical system. It is widely used in pipe wastewater, Situations where toilet sewage is elevated to urban underground pipe networks, such as hotels, guesthouses, shopping malls, commercial office buildings, parking lots, etc.

Sewage Lifting Device and Oil Separation Equipment Selection Guide

Sealed, pollution-free, environmentally friendly

Intelligent design, no one to control

Modular design, beautiful and compact structure

Multiple categories and rich configurations to meet the various needs of users

Easy maintenance and low cost of use

WQ/T series ● Stainless steel water tank, capacity 150L, 250L, 400L, 1000L, 1500L; ●Inlet DN100/80, outlet DN65/50; ● Equipped with 1 or 2 submersible sewage pumps; ● Single pump Qmax: 50m3/h, single pump Hmax: 45m; ● Can be configured with cutting pump or channel pump, suitable for large commercial bodies.
WQ/FT series ●Stainless steel water tank, capacity 650L, 1000L, 1200L, 1500L; ●Inlet DN150/100, outlet DN100/80; ●Equipped with 2 submersible sewage pumps; ●Single pump Qmax: 60m³/h, single pump Hmax: 40m; ●Can be configured with cutting pump or channel pump, suitable for large commercial bodies.

 

WQ/TS series
●PE water tank, single water tank capacity 150L, 250L, 500L;
●Inlet DN100/80, outlet DN65/50;
●Equipped with 1 or 2 submersible sewage pumps;
●Single pump Qmax: 40m³/h, single pump Hmax: 40m;
●Can be configured with cutting pump or channel pump, suitable for large commercial bodies.
WL/T series
●Stainless steel water tank, single water tank capacity 600L, 1000L, 1200L, 1500L;
●Inlet DN150/100, outlet DN80/65;
●Equipped with 2 submersible sewage pumps;
●Single pump Qmax: 60m³/h, single pump Hmax: 38m;
●Can be configured with cutting pump or channel pump, suitable for urban subway.
WL/TS series
●PE water tank, single water tank capacity 460L, 770L;
●Inlet DN150, outlet DN80/65;
●Equipped with 2 submersible sewage pumps;
●Single pump Qmax: 45m³/h, single pump Hmax: 35m;
●Can be configured with cutting pump or channel pump, suitable for urban subway.
WQ/GT oil isolation device built-in series
●Stainless steel water tank, integrated design;
●Inlet DN150, outlet DN65/50;
●Equipped with 2 submersible sewage pumps;
●Single pump Qmax: 50m³/h, single pump Hmax: 30m;
●Can be configured with cutting pump or channel pump, suitable for commercial catering.
WL/GT oil isolation device external series
●Stainless steel water tank, integrated design;
●Inlet DN150, outlet DN65/50;
●Equipped with 2 submersible sewage pumps;
●Single pump Qmax: 50m²/h, single pump Hmax: 30m;
●Only equipped with channel pump, suitable for commercial catering.

1) Various types and water tank volumes are available for customers to choose from.

There are two categories of Shanghai Kaiquan sewage extraction equipment: built-in and external water pump series. The built-in series include WQ/T stainless steel water tank built-in series, WQ/FT backwash series and WQ/TS PE water tank built-in series. The external series include WL /T stainless steel water tank external series, WL/TS460, WL/TS770 subway special closed lifting device series. Each series has a variety of pump specifications and water tank configurations, so there are many types for users to choose from.

2) Small size, saving space.

For the same type of waste extraction device, Kaiquan products choose accessories with smaller specifications and strive to design the product to save installation space.

3) Equipped with chopping type or large channel type impeller, which can cope with various working conditions.

4) The PE water tank type waste extraction device provides multiple specifications and multi-directional interfaces to facilitate on-site installation.

5) The product has a beautiful appearance and is durable.

6) PE water tanks are made from high-quality suppliers, and the product quality is stable and reliable.

Power supply: 380V (±5%), frequency 50Hz;

Sewage pH: 4-10;

Sewage temperature: 0-40℃;

Sewage density: ≤1200kg/m³;

Humidity: 100%.

WQ/T stainless steel water tank built-in series

 

WQ/FT backwash series Model Description
WQ/TS PE water tank built-in series Model Description
WL/T stainless steel water tank external series
WL/TS460 and WL/TS770 subway special series
WQ(L)/GT oil separation lifting device
Electrical control cabinet

This series of products is a comprehensive system solution specially developed by our company for the improvement of urban subway sewage. It mainly includes horizontal submersible sewage pumps (dry and submersible), PE water tanks, local control cabinets, input-type liquid level gauges and valve and pipeline accessories.

This sewage lifting sealing decoration is widely used in the urban subway field. It is mainly used to lift station toilet sewage or other domestic sewage and is installed in the underground station sewage pump room.

The oil separation and lifting device is an integrated device specially used in places such as catering oil and water separation and discharge. It mainly includes an inlet warehouse, a separation warehouse, a lifting warehouse, an oil drainage system, a submersible sewage pump, and an electrical control device.

1) Waste extraction equipment control cabinet

The KQK-T type electric control cabinet is an electric control cabinet equipped for ordinary sewage pumps other than subway sewage pumps. It is used to detect, control and protect the operation of submersible pumps. The system has a liquid level switch to detect the liquid level in the water tank, and realizes the functions of starting the pump at high water levels, stopping the pump at low water levels, and opening additional pumps at ultra-high water levels. The control system has short circuit and overload protection functions. At the same time, it also has motor cavity leakage, oil chamber leakage and winding overheat fault alarm and shutdown protection functions for corresponding pump types. The schematic diagram is as follows:

The control cabinet has manual and automatic working modes, which can realize automatic control of pump start and stop, automatic rotation of two pumps, automatic shutdown on failure, automatic switching and other functions.

2) Subway sewage treatment control cabinet

The control cabinet equipped with the subway sewage extraction closed device is similar to that of traditional sewage extraction. The difference is that the latter uses an input liquid level gauge and a liquid level float switch.The liquid level of the submersible liquid level gauge triggers the start and stop of the two pumps. The float level gauge serves as a redundant safety configuration to prevent the water tank from overflowing when the submersible liquid level gauge fails. The schematic diagram is as follows:

3) Oil isolation equipment control cabinet

The KQK-GT electric control cabinet is a control cabinet equipped for the oil separation lifting device. It is used to detect and protect the operation of the submersible pump. It is also equipped with temperature acquisition measurement and electric heating control. The intelligent oil separation is also equipped with an automatic slag discharge function.

The control cabinet also has the functions of manual and automatic control, automatic shutdown on failure, automatic switching and automatic rotation of two pumps.

main feature

1) Sealed, pollution-free, no odor, environmentally friendly and hygienic;

2) The pump adopts coupling or clamp type installation, which is easy to disassemble and repair;

3) Compact structure and space saving;

4) Intelligent unmanned control, easy to manage.

Product Features

WQ/T stainless steel water tank built-in series

▲Built-in single or two cutting pumps or channel pumps to easily cope with various working conditions;

▲The water pump is coupled and installed to facilitate installation and maintenance;

▲ Equipped with an intelligent control cabinet to effectively protect the water pump; the 304 stainless steel water tank has beautiful appearance, anti-corrosion and durability.

WQ/FT backwash series

▲Two built-in cutting pumps or channel pumps can easily cope with various working conditions;

▲The water pump is coupled and installed to facilitate installation and maintenance;

▲Equipped with an intelligent control cabinet to effectively protect the water pump;

▲304 stainless steel water tank, beautiful appearance, anti-corrosion and durable;

▲The solid-liquid separator is used to effectively block impurities from the water tank and prevent the submersible sewage pump from clogging.

WQ/TS PE water tank built-in series

▲Built-in cutting pump or channel pump can easily cope with various working conditions;

▲The water pump is installed with a clamp for easy installation and maintenance;

▲Equipped with an intelligent control cabinet to effectively protect the water pump;

▲PE material water tank is beautiful in appearance, stable and reliable;

▲Smaller weight, more space-saving, and stronger moisture resistance.

WL/T stainless steel water tank external series

▲Two external cutting pumps or channel pumps can easily cope with various working conditions;

▲The water pump is installed horizontally to increase the effective volume of the water tank;

▲Equipped with an intelligent control cabinet to effectively protect the water pump;

▲The stainless steel water tank has beautiful appearance and strong corrosion resistance;

▲The motor has Class H insulation and can start and stop more than 25 times.

WL/TS460 and WL/TS770 subway special series

Equipped with a cutting pump to easily cope with various impurity working conditions;

▲The redundant design of the liquid level gauge ensures the safety and reliability of the system;

▲The submersible pump is installed horizontally to increase the effective volume of the water tank;

▲Set up a backwash pipe to prevent impurities from depositing at the bottom of the box;

▲The motor has H-class insulation and is equipped with high-temperature resistant bearings;

▲A variety of water tank options are available to meet various customer needs; the high-reliability motor can meet 25 start-stop requirements.

WQ(L)/GT oil separation lifting device

1) Secondary separation technology, which removes residue first and then separates grease, effectively reduces the oil content in wastewater and improves waste oil collection efficiency;

2) The whole box has a fully sealed structure to ensure no odor leakage and is more environmentally friendly;

3) Built-in electric heat transfer device and automatic alkane device to prevent grease condensation under low temperature conditions;

4) Oil separation, improved integrated design, and intelligent automatic control effectively reduce user costs;

5) The oil outlet is equipped with a lens to observe the grease condition, and a stirring device is installed to stir the solid grease.

Technical Parameters

WQ/T stainless steel water tank built-in series

The series of built-in sewage pumps in stainless steel water tanks can be divided into five specifications according to the size of the water tank: 150L, 250L, 400L, 1000L, 1500L. The relevant performance parameters when equipped with different types of submersible sewage pumps are as follows:

serial number Device model flowh(m³) Lift(m) Single pump power(kw) Water pump model Number of pumps
2 WQ/T250 5~15 10~45 0.75~5.5 1
3 WQ/T400 15~25 9~40 0.75~5.5 2
4 WQ/T1000 25~35 3~39 0.75~7.5 2
5 WQ/T1500 35~50 15~35 3~7.5 2
6 WQ/T400 5~25 5~15 1.1~2.2 WQ/ESSeries pump 2
7 WQ/T1000 25~30 10~18 2.2~4 2
8 WQ/T400 10~25 10~20 1.5~4 WQ/SSeries pump 1
9 WQ/T1000 25~35 6~26 1.5~7.5 2
10 WQ/T1500 35~50 12~26 3~7.5 2

Note:

1) The minimum and maximum values of flow rate, head and single pump power in the above table are not one-to-one correspondence. The range is only the maximum and minimum interval.

2) The built-in sewage extraction system of stainless steel water tanks exceeding the above specifications must be customized.

3) The WQ/T150 model adopts fixed installation and non-coupling installation.

WQ/FT backwash series

The PE water tank’s built-in sewage lift can be divided into three specifications according to the size of the water tank: 150L, 250L50OL, and the relevant performance parameters when equipped with different types of submersible sewage pumps are as follows:

serial number Device model flowh(m³) Lift(m) Single pump power(kw) Water pump model Number of pumps
1 WQ/FT650 10~20 8~38 0.75~5.5 WQ/EC Series pump 2
2 WQ/FT1000 20~35 4~38 0.75~7.5 2
3 WQ/FT1200 35~45 6~36 1.5~7.5 2
4 WQ/FT1500 45~60 10~34 3~7.5 2
5 WQ/FT650 10~20 5~25 1.1~4 WQ/ES Series pump 2
6 WQ/FT1000 20~30 5~25 1.1~4 2
7 WQ/T650 10~20 7~18 1.5~4 WQ/S Series pump 2
8 WQ/FT1000 20~35 5~26 1.5~7.5 2
9 WQ/FT1200 35~45 8~26 4~7.5 2
10 WQ/FT1500 45~60 4~23 2.2~7.5 2

Note:

1) The minimum and maximum values of flow rate, head and single pump power in the above table do not correspond to each other. The range is only the maximum and minimum range.

2) The backwash and waste extraction of stainless steel water tanks that exceed the above water tank specifications need to be customized.

WQ/TS PE water tank built-in series

Specification model table

The built-in sewage pump in the PE water tank can be divided into three specifications according to the size of the water tank: 150L 250L 500L. The relevant performance parameters when equipped with different types of submersible sewage pumps are as follows:

serial number Device model flowh(m³) Lift(m) Single pump power(kw) Water pump model Number of pumps
1 WQ/TS150 5~10 8~43 0.75~5.5 WQ/EC Series pump 1
2 WQ/TS250 5~15 6~43 0.75~5.5 2
3 WQ/TS500 15~40 13~35 1.5~7.5 2
4 WQ/TS150 5~10 8~10 1.1 WQ/ES Series pump 1
5 WQ/TS250 5~15 8~25 1.1~4 2
6 WQ/TS500 15~30 5~18 1.5~4 2
7 WQ/TS500 15~40 8~26 1.5~7.5 WQ/S Series pump 2

Note: The minimum and maximum values of flow rate, head and single pump power in the above table are not one-to-one correspondence. The range is only the maximum and minimum interval.

WL/T stainless steel water tank external series

Equipment specification model table

serial number Device model flowh(m³) Lift(m) Single pump power(kw) Water pump model Number of pumps
1 WL/T800 10~35 18~38 4~7.5 WQ/ECT Series pump 2
2 WL/T1200 10~45 15~38 4~7.5 2
3 WL/T1500 10~60 13~38 4~7.5 2
4 WL/T800 10~35 5~26 1.5~7.5 WQ/ST Series pump 2
5 WL/T1200 10~45 5~26 1.5~7.5 2
6 WL/T1500 10~60 5~26 1.5~7.5 2

WL/TS460 and WL/TS770 subway special series

Equipment specification model table

serial number Device model flowh(m³) Lift(m) Single pump power(kw) Water pump model Number of pumps
1 WL/TS460 15~45 26~35 4~7.5 WQ/ECT Series pump 2
2 WL/TS770 15~45 16~35 4~7.5 2
3 WL/TS460 15~45 12~30 4~7.5 WQ/ST Series pump 2
4 WL/TS770 15~45 12~30 4~7.5 2

Note: This series of products only has two water tank specifications: 460L and 770L, and the other specifications are temporarily unavailable.

 

Installation drawing and scope of supply

WQ/T stainless steel water tank built-in series

Scope of supply (equipment details):
name Specification Material Number Remark
1 inlet pipe DN80、DN100 User’s discretion 1 User configured
2 Inlet gate valve DN80、DN100 User’s discretion 1 User configured
3 Control cabinet 11、1控2 1 Standard configuration
4 outlet gate valve DN50、DN65 User’s discretion 1/2 User configured
5 outlet pipe DN50、DN65 User’s discretion 1/2 User configured
6 exhaust pipe DN80、DN100 User’s discretion 1 User configured
7 Outlet mating flange DN50、DN65 304 stainless steel 1/2 Standard configuration
8 Outlet check valve DN50、DN65 cast iron 1/2 Standard configuration
9 Inlet and exhaust matching flange DN80、DN100 User’s discretion 1 User configured
10 Waste extraction device 1 Standard configuration
11 Auxiliary pump According to performance requirements cast iron 1 Optional

Note:

1) The quantity and details of the above equipment are the company’s standard configuration. If there are special requirements, non-standard customization is required;

2) The outlet matching flange of this series of waste extraction devices is Kaiquan’s standard configuration.

WQ/FT backwash series

Scope of supply (equipment details):
serial number name Specification Material Number Remark
1 inlet pipe DN150 User’s discretion 1 User configured
2 Inlet gate valve DN150 User’s discretion 1 User configured
3 Control cabinet 1 control 2 1 Standard configuration
4 outlet pipe DN80, DN100 User’s discretion 1 User configured
5 Exhaust line DN50, DN65 User’s discretion 1 User configured
6 outlet gate valve DN80, DN100 cast iron 1 Standard configuration
7 Waste extraction device 1 Standard configuration
8 Auxiliary pump According to performance requirements cast iron 1 Optional

Note:

1) The quantity and details of the above equipment are the company’s standard configuration. If there are special requirements, non-standard customization is required;

WQ/TS PE water tank built-in series

Scope of supply (equipment details):
serial number name Specification Material quantity Remark
1 inlet pipe DN100 User’s discretion 1 User configured
2 Inlet gate valve DN100 User’s discretion 1 User configured
3 Control cabinet 1 control 2 1 Standard configuration
4 Exhaust line DN50 User’s discretion 1 User configured
5 outlet pipe Configured with pump User’s discretion 1/2 User configured
6 outlet pipe Configured with pump User’s discretion 1/2 User configured
7 Waste extraction device According to performance requirements 1 Standard configuration
8 Auxiliary pump 1 Optional

Note: 1) The quantity and details of the above equipment are the company’s standard configuration. If there are special requirements, they can be customized;

2) The export matching flange is configured by the user;

3) Each set of WQ/TS PE water tanks has a built-in series of wastewater extractors as standard equipped with a hole opener.

WL/T stainless steel water tank external series

Scope of supply (equipment details):
serial number name Specification Material Quantity Remark
1 Inlet gate valve DN150 User’s discretion 1 User configured
2 inlet pipe DN150 User’s discretion 1 User configured
3 Exhaust line DN80 User’s discretion 1 User configured
4 Control cabinet 1 Standard configuration
5 outlet pipe DN80/DN65 User’s discretion 1 User configured
6 Waste extraction equipment 1 Standard configuration
7 Auxiliary pump cast iron 1 Optional

Note: The quantity and details of the above equipment are the company’s standard configuration. If there are special requirements, they can be customized.

WL/TS460 and WL/TS770 subway special series

serial number serial number Specification Material quantity Remark
1 Inlet gate valve DN150 User’s discretion 1 User configured
2 inlet pipe DN150 User’s discretion 1 User configured
3 diaphragm pump DN50 cast iron 1 Optional
4 Exhaust line DN80 User’s discretion 1 User configured
5 Control cabinet 1 Standard configuration
6 outlet pipe DN80/DN65 User’s discretion 1 User configured
7 Waste extraction equipment 1 Standard configuration
8 Auxiliary pump cast iron 1 Optional

WQ(L)/GT oil separation lifting device

Scope of supply (equipment details)
serial number name Specification Material Quantity Remark
1 Inlet gate valve DN100/DN150 User’s discretion 1 User configured
2 inlet pipe DN100/DN150 User’s discretion 1 User configured
3 Control cabinet 1 Device configuration
4 Exhaust line DN50 User’s discretion 1 User configured
5 outlet pipe DN65/DN50 User’s discretion 1 User configured
6 outlet gate valve DN65/DN50 User’s discretion 1 User configured
7 Oil trap 1 Device configuration
8 Auxiliary pump cast iron 1 Optional
WQ/TS PE water tank built-in series product extension

In order to meet the requirements of some customers’ working conditions that require larger water tanks, Kaiquan’s PE waste extraction products can be connected in two or three water tanks in parallel. Three or more water tanks in parallel can be arranged in a linear or L-shape.Its appearance and installation requirements are as follows: In order to meet the requirements of some customers’ working conditions that require a larger water tank volume, Kaiquan’s PE waste extraction products can be connected in parallel with two or three water tanks.Three or more water tanks connected in parallel can be arranged in a straight line or L shape. Their appearance and installation requirements are as follows:

Device model Equipment dimensions Installation space Remark
long/mm Width/mm high/mm long/mm Width/mm high/mm
WQ/TS1000 2350 900 880 2650 1200 1100
WQ/TS1500 3600 900 880 3900 1200 1100 linear layout
2350 1950 880 2650 2250 1100 L-shaped layout

 

Note: 1) WQ/TS1000 is composed of two sets of 500L water tanks connected in parallel;

2) WQ/TS1500 is composed of three sets of 500L water tanks connected in parallel;

3) If an auxiliary pump is required, the length and width of the above installation space will be increased by 500mm.

Special series of submersible sewage pumps for subway sewage extraction

In order to adapt to the special working conditions of the subway environment, Shanghai Kaiquan has specially developed the WQ/ECT pump and WQ/ST pump for subway sewage extraction. The performance parameters of the two are as follows:

serial number Device model Limited Data(m³/h) Rated lift(m) Single pump power(kW)
1 WQ/ECT 30 25 4
2 30 30 5.5
3 30 35 7.5
4 WQ/ST 25 20 4
5 25 25 5.5
6 20 35 7.5
WQ(L)/GT oil separation lifting device Application scenarios

Mainly used in hotels, restaurants, public canteens, chain restaurants, shopping malls, meat processing companies and other places.