TDG Series Boiler Feed Pump

The TDG series boiler feed pump is a double-shell multistage centrifugal pump with horizontal center support. The water inlet and outlet are both vertically upward. The pump shaft seal adopts a containerized mechanical seal, and the mechanical seal has a self-flushing cooling system, which is reliable and safe. The entire series adopts cooling water integrated pipelines, and various monitoring instruments are complete to achieve full pressure and temperature monitoring. Vibration, speed and reverse protection and other control requirements can be added according to user requirements.
The pump is driven by a motor through a diaphragm coupling, and can also be driven by a small steam turbine according to user needs, and is driven by a hydraulic coupling. From the transmission direction, the pump rotates clockwise.
This product complies with JB/T8059-2020 <<Technical Conditions for High-Pressure Boiler Feed Pumps>>.
This product is designed and manufactured in accordance with API610 specifications.

TDG Series Boiler Feed Pump

Standard design
Product design meets JB/T8059 design specifications
Best performance
Excellent hydraulic model matches precision casting process to ensure high efficiency and low cavitation
Reliable operation
Double shell, horizontal centerline support, balance plate fully balances axial force
Easy maintenance
Containerized mechanical seal, inner shell disassembly tool for easy disassembly

Name Material Standard Name Material Standard
Casing/Pump Cover 20Mn GB/T11352 Balance disc Stainless steel 2Cr13 GB/T1220
Inner Casing Stainless steel ZG1Cr13 GB/T699 Balance plate Stainless steel 3Cr13 GB/T1220
(Balance disc seat)
Impeller Stainless steel ZG1Cr13 GB/T1220 Sealing ring Stainless steel GB/T1220
1Cr13MoS
(RWA350)
Guide Vanes Stainless steel ZG1Cr13 GB/T1220 Guide vane sleeve Stainless steel GB/T1220
1Cr13MoS
(RWA350)
Shaft Alloy Steel 40CrV GB/T3077 Bearing frame Cast Steel ZG270-500 GB/T11352

 

 

Pump Model Imported flange Outlet flange
DN X d K D f1/f2 C n-ΦL Mating flange standards and pressure ratings DN  X d K D f1/f2 C n-ΦL Matching flange standards and pressure ratings
TDG45-80 80 135 160 200 3/- 20 8-φ18 GB/T9124,PN16、RF 65 109 170 220 -/4.5 34 8-φ26 GB/T9124、 PN100、 F
TDG65-80 100 158 180 220 3/- 20 8-φ18 GB/T9124,PN16、RF 65 109 170 220 -/4.5 34 8-φ26 GB/T9124、 PN100、 F
TDG85-80 100 158 180 220 3/- 20 8-φ18 GB/T9124,PN16、RF 80 120 180 230 -/4.5 36 8-φ26 GB/T9124、 PN100、 F
TDG120-80 150 218 250 300 3/- 28 8-φ26 GB/T9124,PN25、RF 100 149 210 265 -/5 40 8-φ30 GB/T9124、 PN100、 F
TDG150-100 150 218 250 300 3/- 28 8-φ26 GB/T9124,PN25、RF 100 149 210 265 -/5 40 8-φ30 GB/T9124、 PN100、 F
TDG200-100 200 278 310 360 3/- 30 12-φ26 GB/T9124,PN25、RF 150 203 290 355 -/5 44 12-φ33 GB/T9124、 PN100、 F
TDG280-100 200 278 310 360 3/- 30 12-φ26 GB/T9124,PN25、RF 150 203 290 355 -/5 44 12-φ33 GB/T9124、 PN100、 F
TDG65-120 100 162 190 235 3/- 24 8-φ22 GB/T9124,PN25、RF 65 109 170 220 -/4.5 34 8-φ26 GB/T9124、 PN160、 F
TDG85-120 100 162 190 235 3/- 24 8-φ22 GB/T9124,PN25、RF 80 120 180 230 -/4.5 36 8-φ26 GB/T9124、 PN160、 F
TDG120-120 150 218 250 300 3/- 28 8-φ26 GB/T9124,PN25、RF 100 149 210 265 -/5 40 8-φ30 GB/T9124、 PN160、 F
TDG160-120 150 218 250 300 3/- 28 8-φ26 GB/T9124,PN25、RF 100 149 210 265 -/5 40 8-φ30 GB/T9124、 PN160、 F
TDG220-160 200 278 310 360 3/- 30 12-φ26 GB/T9124,PN25、RF 150 203 320 390 -/5 68 12-φ36 GB/T9124、 PN250、 F
TDG270-150 250 335 370 425 3/- 32 12-φ30 GB/T9124,PN25、RF 150 203 320 390 -/5 68 12-φ36 GB/T9124、 PN250、 F
TDG320-150 250 335 370 425 3/- 32 12-φ30 GB/T9124,PN25、RF 150 203 320 390 -/5 68 12-φ36 GB/T9124、 PN250、 F
TDG360-164 250 335 370 425 3/- 32 12-φ30 GB/T9124,PN25、RF 150 203 320 390 -/5 68 12-φ36 GB/T9124、 PN250、 F
TDG160-170 150 218 250 300 3/- 28 8-φ26 GB/T9124,PN25、RF 100 149 235 300 -/5 54 8-φ33 GB/T9124、 PN250、 F
TDG200-170 150 218 250 300 3/- 28 8-φ26 GB/T9124,PN25、RF 150 203 320 390 -/5 68 12-φ36 GB/T9124、 PN250、 F
TDG250-170 250 335 370 425 3/- 32 12-φ30 GB/T9124,PN25、RF 150 203 320 390 -/5 68 12-φ36 GB/T9124、 PN250、 F
TDG360-175 250 335 370 425 3/- 32 12-φ30 GB/T9124,PN25、RF 150 203 320 390 -/5 68 12-φ36 GB/T9124、 PN250、 F
TDG440-156 250 335 370 425 3/- 32 12-φ30 GB/T9124,PN25、RF 200 259 400 485 -/5 82 12-φ42 GB/T9124、 PN250、 F
TDG500-205 300 395 430 485 4/- 34 16-φ30 GB/T9124,PN25、RF 200 259 400 485 -/5 82 12-φ42 GB/T9124、 PN250、 F
TDG570-215 300 395 430 485 4/- 34 16-φ30 GB/T9124,PN25、RF 200 259 400 485 -/5 82 12-φ42 GB/T9124、 PN250、 F

Permissible forces and moments acting on the flange

Pump Model Imported Exit
DN Fy Fz Fx ≥Fb My Mz Mx ∑Mb DN Fy Fz Fx ∑Fb My Mz Mx ∑Mb
TDG45-80 80 2140 1780 2660 3860 1900 940 1440 2560 65 1700 2100 1850 3300 1100 1200 1500 2200
TDG65-80 100 2840 2320 3560 5120 2660 1360 2000 3600 65 1700 2100 1850 3300 1100 1200 1500 2200
TDG85-80 100 2840 2320 3560 5120 2660 1360 2000 3600 80 2140 1780 2660 3860 1900 940 1440 2560
TDG120-80 150 4980 4100 6220 8960 4600 2360 3520 6260 100 2840 2320 3560 5120 2660 1360 2000 3600
TDG150-100 150 4980 4100 6220 8960 4600 2360 3520 6260 100 2840 2320 3560 5120 2660 1360 2000 3600
TDG200-100 200 7560 6220 9780 13840 7060 3520 5160 9420 150 4980 4100 6220 8960 4600 2360 3520 6260
TDG280-100 200 7560 6220 9780 13840 7060 3520 5160 9420 150 4980 4100 6220 8960 4600 2360 3520 6260
TDG65-120 100 2840 2320 3560 5120 2660 1360 2000 3600 65 1700 2100 1850 3300 1100 1200 1500 2200
TDG85-120 100 2840 2320 3560 5120 2660 1360 2000 3600 80 2140 1780 2660 3860 1900 940 1440 2560
TDG120-120 150 4980 4100 6220 8960 4600 2360 3520 6260 100 2840 2320 3560 5120 2660 1360 2000 3600
TDG160-120 150 4980 4100 6220 8960 4600 2360 3520 6260 100 2840 2320 3560 5120 2660 1360 2000 3600
TDG220-160 200 7560 6220 9780 13840 7060 3520 5160 9420 150 4980 4100 6220 8960 4600 2360 3520 6260
TDG270-150 250 10680 8900 13340 19260 10040 4880 7600 13500 150 4980 4100 6220 8960 4600 2360 3520 6260
TDG320-150 250 10680 8900 13340 19260 10040 4880 7600 13500 150 4980 4100 6220 8960 4600 2360 3520 6260
TDG360-164 250 10680 8900 13340 19260 10040 4880 7600 13500 150 4980 4100 6220 8960 4600 2360 3520 6260
TDG160-170 150 4980 4100 6220 8960 4600 2360 3520 6260 100 2840 2320 3560 5120 2660 1360 2000 3600
TDG200-170 150 4980 4100 6220 8960 4600 2360 3520 6260 150 4980 4100 6220 8960 4600 2360 3520 6260
TDG250-170 250 10680 8900 13340 19260 10040 4880 7600 13500 150 4980 4100 6220 8960 4600 2360 3520 6260
TDG360-175 250 10680 8900 13340 19260 10040 4880 7600 13500 150 4980 4100 6220 8960 4600 2360 3520 6260
TDG440-156 250 10680 8900 13340 19260 10040 4880 7600 13500 200 7560 6220 9780 13840 7060 3520 5160 9420
TDG500-205 300 13340 10680 16000 23400 12200 5960 9220 16420 200 7560 6220 9780 13840 7060 3520 5160 9420
TDG570-215 300 13340 10680 16000 23400 12200 5960 9220 16420 200 7560 6220 9780 13840 7060 3520 5160 9420

 Pump model Cooling water pipe Sliding bearing lubricating oil pipe
Medium Interface size (flange connection) Temperature ℃ Pressure (MPa) Flow rate (m³/h) Oil inlet pipe interface size (flange connection) Oil outlet pipe interface size (flange connection)
TDG45-80 Industrial water DN50,PN40 ≤30℃   0.2~0.4 3~5 DN50,PN40 DN80,PN16
TDG65-80 Industrial water DN50,PN40 ≤30℃   0.2~0.4 3~5 DN50,PN40 DN80,PN16
TDG85-80 Industrial water DN50,PN40 ≤30℃   0.2~0.4 3~5 DN50,PN40 DN80,PN16
TDG120-80 Industrial water DN50,PN40 ≤30℃   0.2~0.4 5~7 DN50,PN40 DN80,PN16
TDG150-100 Industrial water DN50,PN40 ≤30℃   0.2~0.4 5~7 DN50,PN40 DN80,PN16
TDG200-100 Industrial water DN50,PN40 ≤30℃   0.2~0.4 5~7 DN50,PN40 DN80,PN16
TDG280-100 Industrial water DN50,PN40 ≤30℃   0.2~0.4 5~7 DN50,PN40 DN80,PN16
TDG65-120 Industrial water DN50,PN40 ≤30℃   0.2~0.4 3~5 DN50,PN40 DN80,PN16
TDG85-120 Industrial water DN50,PN40 ≤30℃   0.2~0.4 3~5 DN50,PN40 DN80,PN16
TDG120-120 Industrial water DN50,PN40 ≤30℃   0.2~0.4 3~5 DN50,PN40 DN80,PN16
TDG160-120 Industrial water DN50,PN40 ≤30℃   0.2~0.4 3~5 DN50,PN40 DN80,PN16
TDG220-160 Industrial water DN50,PN40 ≤30℃   0.2~0.4 5~7 DN50,PN40 DN80,PN16
TDG270-150 Industrial water DN50,PN40 ≤30℃   0.2~0.4 5~7 DN50,PN40 DN80,PN16
TDG320-150 Industrial water DN50,PN40 ≤30℃   0.2~0.4 5~7 DN50,PN40 DN80,PN16
TDG360-164 Industrial water DN50,PN40 ≤30℃   0.2~0.4 5~7 DN50,PN40 DN80,PN16
TDG160-170 Industrial water DN50,PN40 ≤30℃   0.2~0.4 5~7 DN50,PN40 DN80,PN16
TDG200-170 Industrial water DN50,PN40 ≤30℃   0.2~0.4 5~7 DN50,PN40 DN80,PN16
TDG250-170 Industrial water DN50,PN40 ≤30℃   0.2~0.4 5~7 DN50,PN40 DN80,PN16
TDG360-175 Industrial water DN50,PN40 ≤30℃   0.2~0.4 5~7 DN50,PN40 DN80,PN16
TDG440-156 Industrial water DN50,PN40 ≤30℃   0.2~0.4 5~7 DN50,PN40 DN80,PN16
TDG500-205 Industrial water DN50,PN40 ≤30℃   0.2~0.4 5~7 DN50,PN40 DN80,PN16
TDG570-215 Industrial water DN50,PN40 ≤30℃   0.2~0.4 5~7 DN50,PN40 DN80,PN16
Typical applications

TDG series boiler feed water pumps are mainly used to pump boiler feed water in power plants, petrochemical, coal chemical and other systems, and can also be used in other applications of conveying high-pressure clean water.

Working conditions

Flow rate: 35~620m³/h
Lift: 400~2000m
Speed: 2980r/min
Medium: boiler feed water, clean water or other liquids with physical and chemical properties similar to water
Medium temperature: <200℃

Performance range

Discharge pressure (p): 4~20MPa
Flow rate Q=35~620m³/h
Head H=400~2000m
Working temperature t=0~200C
Standard speed n=2980r/min

Series of Kaiquan Boiler Feed Water Pumps

The DG series boiler feed water pump is a segmented multi-stage centrifugal pump, with the inlet section, middle section, and outlet section connected as one unit using tightening bolts. The inlet and outlet are both oriented vertically upwards. The static seals between the water inlet section, middle section, and outlet section use dual seals of metal surface sealing and “O”-shaped sealing rings. The hydraulic components are designed and optimized using CFD flow field analysis technology, providing excellent performance. The impeller and guide vanes are precision-cast, with smooth flow channels, high dimensional accuracy, and high efficiency. The rotor is dynamically balanced, with a precision level higher than the industry standard. When viewed from the drive direction, the pump rotates clockwise. The DG type medium and low-pressure boiler feed water pumps use a base support structure and comply with the standard of GB/T 5657-1995 “Centrifugal Pump Technical Conditions (III)”.

ZDG high-temperature boiler feed water pumps and DG type medium and high-pressure boiler feed water pumps adopt a center support structure, coupled with a slip system to effectively compensate for thermal deformation. ZDG high-temperature boiler feed water pumps and DG type medium and high-pressure boiler feed water pumps use an integrated cooling water piping system for water supply, and users can choose to use a mechanical seal self-flushing system according to their requirements, eliminating the need for users to provide flushing water for the mechanical seal, making installation and use more convenient.