W-Series Fire Stable Water Supply Equipment
W series fire booster and stabilized water supply equipment is a special equipment for stabilizing the water supply pressure of fire protection pipe networks. The voltage stabilizing equipment is matched with the automatic control fire pump set to achieve linkage and is equipped with an independent electrical control device.
It is suitable for fire hydrant water supply systems and automatic sprinkler fire extinguishing systems in multi-story and high-rise civil buildings, public buildings, industrial and mining enterprises, etc. Fire water supply system. The product meets the national standard GB27898.3-2011 《Fixed Fire Water Supply Equipment Part 3: Fire Pressurized and Stabilized Water Supply Equipment》 and complies with CCCF voluntary certification requirements.
Product Overview
1.Product introduction:
The pressure-stabilizing pump in the W series fire booster and stabilized water supply equipment is the third generation lightweight vertical multi-stage centrifugal pump KQDP series. The water pump performance meets the national standard GB/T5657-2013 《Technical Conditions for Centrifugal Pumps (III)》 and is suitable for fire protection When stabilizing the voltage, it should meet the national standard GB27898.3-2011 《Fixed Fire Water Supply Equipment Part 3: Fire Pressure Stabilized Water Supply Equipment》 GB50974-2014《Technical Specifications for Fire Water Supply and Fire Hydrant Systems》. The basic type of equipment includes a unit composed of two voltage stabilizing pumps (one for use and one for backup), a pressure tank and a control cabinet. The overall skid-mounted type can also be made according to actual working conditions.
The design of W series fire booster and regulated water supply equipment fully draws on the emerging technologies and mature experience of municipal water supply in recent years, and combines the development of Internet of Things technology in recent years to develop and produce a new, multi-functional integrated type with good applicability. , safe and reliable fire extinguishing facilities
2.Product design basis:
Technical Specifications: GB50974-2014 《Technical Specifications for Fire Water Supply and Fire Hydrant Systems》
Product Standard: GB27898-2011 《Fixed Fire Water Supply Equipment Part 3 Fire Pressurization and Regulated Voltage Water Supply Equipment》
Product standard: GB16806-2006 《Firefighting Linkage Control System》
Other standards: GB 50974-2014 《Technical Specifications for Fire Water Supply and Fire Hydrants》Implementation Guide;
Reference standard atlas:
15S909 《Atlas of Technical Specifications for Fire Water Supply and Fire Hydrants》
17S205 《Selection and Installation of Fire Water Supply Stabilizing Equipment》
01S105 《Selection and installation of commonly used small instruments and valves》
- Product Display
- Equipment Principle
- System Principle
W series fire booster and regulated water supply equipment consists of a stabilized water pump (including a stabilized main pump and a stabilized backup pump), a pressure tank, a fire electrical control cabinet, and control instruments. The basic structure diagram of the equipment is shown in Figure 3.1.1:
The conventional product of W series fire booster and regulated water supply equipment is a water supply unit with two water pumps (one in use and one in standby) arranged centrally. The equipment schematic diagram is shown in Figure 4.1.1:

| System. | NO. | Name | Specification | Unit | Quantity |
| Regulators pump | A1 | Stabilizer pump (electric) | set | 2 | |
| A2 | Safety relief valve | DN50 | piece | 1 | |
| A3 | Wafer type silencer check valve | piece | 2 | ||
| A4 | Wafer butterfly valve | piece | 2 | ||
| A5 | Pressure Sensor | piece | 1 | ||
| A6 | pressure gauge | piece | 3 | ||
| A7 | vacuum gauge | piece | 2 | ||
| straw
Connecting pipe |
B1 | Fire gate valve | piece | 2 | |
| B2 | Prevent cyclone | piece | 2 | ||
| Figure 4.1.1 Schematic diagram of W series fire booster and regulated water supply equipment. | |||||

Part number description: 1. Pressure tank 2. Safety valve 3. Pressure gauge 4. Vacuum gauge 5. Pressure sensor 6. Check valve 7. Gate valve 8. Flow switch
1.Stabilized water pump

- High efficiency and more energy saving
The water pump has excellent performance and high efficiency. The efficiency indicator has reached the international advanced level. The energy efficiency index has reached MEI≥0.7, which is much higher than the national energy-saving standard. It has passed the national pump energy-saving certification.
- Beautiful appearance
The shell is made of stainless steel plate, the outer surface is polished, smooth and beautiful, with a modern flavor
- Corrosion resistance and long life
Adopt new industrial and hydraulic design methods and perform finite element strength analysis. Stainless steel castings are precision cast with silicon melt and have high dimensional accuracy. The rusty iron parts are mechanically shaped with molding sand, and the surface is coated with electrophoretic paint to have a smooth appearance and corrosion resistance.
- Clean and environmentally friendly
The parts are made of stainless steel plates, which is green and environmentally friendly, will not cause secondary pollution of water quality, and meets the requirements of health standards.
The third generation KQDP light vertical multi-stage centrifugal pump is designed with energy saving, environmental protection, safety and reliability as its design concepts, adopts new industrial and hydraulic design methods, and is the latest independently developed new generation product. The products are suitable for different temperature, flow and pressure ranges, and can transport various media from tap water to industrial liquids. They are widely used in water supply, industrial pressurization, industrial liquid transportation, HVAC, irrigation and water treatment and other fields. KQDP is suitable for non-corrosive liquids, and the product complies with GB/T5657-2013 《Technical Conditions for Centrifugal Pumps (III)
2.Fire electrical control cabinet
The specific functions of the fire electrical control cabinet supporting the W series fire booster and regulated water supply equipment are as follows:
| Stabilized water pump control. | Protection grade IP54 or IP55 | Real-time data display |
| Automatic power frequency inspection | Data storage function | Historical data export function |
| Fault information display | Dual power switching | Historical data query function |
3.Unit structure
The W series fire booster and stabilized water supply equipment is based on the number of stabilized water pumps in the equipment unit, one for use and one for standby. The unit pipes are welded pipes, and the pipe connection method is flange connection.
The standard type is a stabilized pump unit (excluding import), control cabinet and pressure tank installed separately. The outlet of each stabilized water pump contains a check valve, a butterfly valve for maintenance, a pressure gauge, a manifold, and a pressure detection component. The safety valve on the main manifold of the unit is optional, and one side can be equipped with a reducing pipe and a metal hose to facilitate connection with the outlet pipe of the on-site pressure tank.

The overall skid-mounted type is a pressure-stabilizing pump unit (excluding imports), control cabinet and pressure tank. It adopts an integral skid-mounted base. The outlet of each pressure-stabilizing water pump contains a check valve, a butterfly valve for maintenance, a pressure gauge, a manifold, and pressure detection components. The safety valve on the unit’s main converging pipe is optional, and the diameter of the main pipe is consistent with the diameter of the outlet of the pressure tank.

- Pressure tank
The pressure tanks used in W series fire booster and stabilized water supply equipment are mainly vertical diaphragm pressure tanks SQL series. The specifications and models for evidence collection and the corresponding available effective water volume are as shown in the following table:
| 5. Pressure tank specifications and models. | 6. Working pressure range (MPa) | 7. Total volume (m³) | 8. Effective water solvent. (m³) |
| SQL600 | 0.6、1.0、1.6、2.0、2.5 | 0.3 | 0.15 |
| SQL800 | 0.6、1.0、1.6、2.0、2.5 | 0.8 | 0.3 |
| SQL1000 | 0.6、1.0、1.6、2.0、2.5 | 1.3 | 0.3、0.45 |
| SQL1200 | 0.6、1.0、1.6、2.0、2.5 | 2.2 | 0.45 |


W series fire pressurized and regulated water supply equipment standard installation ruler:

- Safety valve (DN50 drain port) 2. Metal hose connection 3. Pressure gauge 4. Pressure sensor
Specifications and performance parameters of box-type voltage regulator series:

Standard installation dimensions of pump station:



| Serial number | Name | Serial number | Name |
| 1 | Firefighting stabilized water pump unit | 9 | Wafer handle butterfly valve (with self-locking)Wafer handle butterfly valve (with self-locking) |
| 2 | SQL series vertical diaphragm pressure tank | 10 | Level gauge |
| 3 | Voltage stabilizing control cabinet | 11 | Breather tube (with insect net)) |
| 4 | Safety valve (optional)) | 12 | Butterfly valve (model optional) |
| 5 | Wafer handle butterfly valve (with self-locking) DN100 | 13 | Y type filter |
| 6 | Flow Switch | 14 | Pressure reducing valve |
| 7 | Wafer check valve | 15 | Remote control float valve |
| 8 | Wafer handle butterfly valve (with self-locking) DN80 | 16 | Channel steel |
The ordering of this product is not restricted by the performance parameters listed in the document. Our company can produce it according to the actual flow, lift, power and other parameters required by the project as well as different system types.
If you have special requirements, please specify them when ordering. Our company will produce them according to the actual situation.
When ordering, please provide the complete equipment model or basic parameters such as flow rate and head at the operating point required by the user.